The online residual chlorine analyzer is an online intelligent residual chlorine detector produced by our company with imported technology. It adopts imported components and permeable membrane heads, based on the latest polarographic analysis technology, advanced production processes, and SMT. This series of advanced analysis technologies ensures the long-term stable reliability and accuracy of the instrument during operation. It has functions such as 485 communication.
| Measurement Range | 0~5mg/L |
| Resolution | 0.01mg/L |
| Accuracy | 5%±0.03mg/L (whichever is larger) |
| Control Range | 0~5mg/L |
| Temperature Range | 0~100℃ |
| Required Sample Flow Rate | 80L/H |
| Output Signal | Isolated 4~20mA output |
| Control Output Method | ON/OFF relay output contact |
| Relay Load Capacity | Max 230VAC 5A; Max 115VAC 10A |
| Relay Hysteresis | Freely adjustable |
| Current Output Load | Maximum allowable load 500Ω |
| Insulation Degree to Ground Voltage | Minimum 500VDC |
| Working Voltage | 230VAC±15%, 50/60Hz |
| Dimensions | 96×96×125mm |
| Opening Dimensions | 1/4DIN |
| Weight | 0.96Kg |
| Working Conditions of the Instrument | Ambient temperature: 5~35℃; Relative air humidity: ≤80%; No strong magnetic field interference around except the Earth's magnetic field |
Function Configuration | Simultaneous display of residual chlorine value, temperature, and 4~20mA current; high/low point ON/OFF output; high/low point alarm; 4~20mA current output (optional); RS485 communication interface (optional). One-month measurement data storage (optional). |
The online residual chlorine analyzer is highly intelligent and flexible, capable of simultaneously measuring residual chlorine, hypochlorous acid, pH, and temperature.
It is widely used in industries such as electric power, water supply, pharmaceuticals, chemical engineering, and food for continuous measurement of residual chlorine and pH value in water.
Large dot-matrix LCD.
Simultaneous display of multiple parameters: Residual chlorine value, hypochlorous acid value, pH value, temperature, output current, etc., intuitive and easy to read, with range over-limit prompt.
Functions of restoring factory settings and slope correction.
Manual/automatic pH compensation function and temperature compensation function.
Communication Function (Optional): Equipped with an RS-485 communication interface (partially compatible with MODBUS protocol); the residual chlorine value corresponding to 4~20mA current output can be set arbitrarily.
Photoelectrically isolated 4-20mA current output.
An arbitrary hysteresis setting function to avoid frequent action of switching relays, with functions of setting the switch on/off.
Watchdog function: Ensures the instrument will not crash.
Core components are from well-known brands.
Electrode cable length: 5m as standard if not specified.
Electrode installation method.
Power supply: AC220V as standard if not specified.
Customization available for special requirements.
Contact Huaqiang for Wholesale Water Treatment Equipment